BENTLY NEVADA 本特利 350060@@2022资料已更新

IS210DTURH1AA
IS210WSVOH1A
IS215ACLEH1C
IS215UCCAM03A
IS215VAMBH1A
IS215VCMIH2B
IS215VCMIH2C
IS215VPROH1B
IS215VPROH2B
IS220PAICH2A
IS220PDIOH1A
IS220PPROH1A
IS220PSFDH1A
IS220PTCCH2A
IS220PTURH1A
IS220UCSAH1A
IS400JGPAG1A
IS415UCVGH1A
IS415UCVHH1A
IS200ACLEH1B
IS200ACLEH1A
IS200AVIFH1A
IS200BAIAH1B
IS200BICHH1A

分类: 标签:

Description

BENTLY NEVADA 本特利 350060

BENTLY NEVADA 本特利 350060

BENTLY NEVADA 本特利 350060

PanelView™ 5310 终端是通过EtherNet/IP 网络监视和控制ControlLogix® 5570 和CompactLogix™ L1、L2 和 L3 控制器所连接设备的操作员界面设备。其动画图形和文本显示便于操作员查看机器或过程的工作状态。操作员通过使用触摸屏与控制系统进行交互。
PanelView 5310 终端具有以下特性和功能:
• 紧密集成的控制和设计环境有助于在 PanelView 5310 终端和Logix 平台之间共享信息。
• Studio 5000® 环境为 View Designer 和 Logix Designer 应用程序提供单点访问途径。
• 可连接一个版本 27 或更高版本固件的 ControlLogix 5570 或CompactLogix L1、L2 或 L3 控制器。
• 最多支持 50 个用户自定义画面。
• 最多支持 500 个 Logix-based 报警。
• 易配置的屏幕导航菜单。

trending and alarming functions. Controller executes open loop
and closed loop control function.
Freelance 800F DigiVis Operator Level
DigiVis operator stations use PC hardware, either standard commercial
Business PCs can also be industrial-grade PCs and run on Micro-
under soft Windows operating system. DigiVis supports dual-screen display operation
operating technology, that is to say, two operations can be performed using one PC
station and operate with a mouse and a keyboard.
Operator level can install one engineering station and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to
The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.

Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to the type and number of system process signals.
AC800F controller connects remote I/O or field device via fieldbus
ready.

 

system communication
Communication between operator level and process control level using TCP/IP
Protocol system bus (based on Ethernet), you can choose different
transmission medium such as AUI, twisted pair, fiber optic or coaxial cable.
Freelance OPC server for connecting to higher-level operators
station (800xA) or other OPC client. Freelance Control System
Real-time process values ??and alarms in the system can be