WOODWARD 9907-838
WOODWARD 9907-838
WOODWARD 9907-838
SC72便携式电导率仪小型轻量、便于使用、防水等特点,非常适用于现场以及实验室应用。这款便携式电导率仪具有数据存储、报警和自诊断功能等先进特性。
与多种电极结合使用,可以使便携式电导率仪SC72满足任何电导率应用的需要。YOKOGAWA提供监测或控制液体和溶液中电导率值的优良的在线分析仪器。现在,YOKOGAWA提供四线制电导率控制器(SC402G),两线制电导率变送器(SC202SJ、SC202G)和盘装式电导率控制器(SC100)。
当使用转换器、变送器时,为了能精确地测量液体电导率值,YOKOGAWA也将提供各种传感器。
YOKOGAWA的转换器、变送器与其传感器相结合可满足苛刻的要求。YOKOGAWA的仪器除可以进行标准电厂和化工应用方面传统的水质测量以外,还满足不断增长的半导体和医药等行业的超纯水需求。
user program.
●The programming language strictly complies with the international standard of IEC61131-3, and has
There are high-performance graphics editing functions:
– Function Block Diagram (FBD)
-Ladder Diagram (LD)
– Instruction List (IL)
– Sequence Control Chart (SFC)
. Structured Text (ST)
●Extensive function block library, user-defined function blocks can also be added
Added to it, the macro library and graphic symbols can be customized for the user.
Blocks can create graphics and operator panels.
●Any standard can be integrated by means of GSD file import
PROFIBUS-DP and PA devices, and through user-defined pairing
dialog box to design the configuration window for these devices.
●Profibus field controller can be integrated through FDT/DTM technology
line equipment
system structure
The Freelance 800F process control system is divided into operator levels
and process control level. The operator level contains controls for operation and display.
Archiving and logging, trending and alarming functions. Controller executes open loop
and closed loop control function.
Freelance 800F DigiVis Operator Level
DigiVis operator stations use PC hardware, either standard commercial
Business PCs can also be industrial-grade PCs and run on Micro-
under soft Windows operating system. DigiVis supports dual-screen display operation
operating technology, that is to say, two operations can be performed using one PC
station and operate with a mouse and a keyboard.
Operator level can install one engineering station and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to
The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.
Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to the type and number of system process signals.
AC800F controller connects remote I/O or field device via fieldbus
ready.
system communication
Communication between operator level and process control level using TCP/IP
Protocol system bus (based