IS200UCVEH2AE
IS200UCVEH2AE
IS200UCVEH2AE
ATV312 变频器用于功率范围为 0.18 至 15 kW的200…600 V三相异步电机。
ATV312 变频器具有功能强劲、结构紧凑和易于安装的特点。其集成的多种功能使其特别适合于简单工业机械应用。我们在产品设计阶段就充分考虑了安装和使用中相关的约束条件,从而能够为简单机器的制造商和安装者提供一种可靠的、高性价比的解决方案。采用各种可选购的通讯卡,ATV312 变频器可完美集成到主控制系统架构中。
解决方案示例:
·用于下载、编辑和保存变频器配置的多种选购件均应用了不同的工具,例如SoMove 上位机软件、用于手机调试的 SoMove Mobile 软件、远程显示终端、简易下载器及多功能下载器配置工具。
·只需将变频器 I/O 端子卡更换为一张通讯卡,即可应用工业通讯总线和网络。
·与 ATV12 系列变频器采用统一的用户界面,使得安装更加简便,用户操作更加顺畅
communication with the system network diginet s (iee802.3 Ethernet standard)
Interface.
Basic characteristics:
1ee802.3 Ethernet standard
o
Ei801f provides 10base2 thin cable communication interface
Ei802f provides 10BASE5 thick cable connection (through AUI interface)
Ei803f provides 10Base-T twisted pair communication interface
32-bit data bus, 100 mb/s
DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4%
Optional ram backup battery
Fieldbus interface replacement card fi830f/fi820f/fi810f
Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS,
Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still
It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other
Redundant basic unit pm802f) and can be plugged in and out and replaced online.
Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd
One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one city (subsystem) of industrial “system can
Connect 4960 fieldbus devices (10000 i/0).
Fi820f: two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association
Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation
Away. And the redundant operation is realized by two redundant field controllers.
Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station
The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS