GE DS200TCPDG2BEC
GE DS200TCPDG2BEC
GE DS200TCPDG2BEC
模块化结构,具备通信功能
SIRIUS 8WD信号灯柱和信号灯既可以安装在机器上,也可J‘以用于自动化生产线,它们是用于声光报警的最佳设备。
SIRIUS 8WD产品是高度模块化的设备,其设计灵活,具有通用性,并且可以实现快速牢固的安装。因为具有高的耐用性和强大的保护功能,这些产品能够抵抗强烈的冲击和振动。并且可以通过AS-Interface实现通信Win-SIMOCODE-DP是进行参数化,操作,诊断,及监测软件,安装在PC或PU上,共有两个版本Win-SIMOCODE-DP/Smart和Win-SIMOCODE-DP/Professional。操作和维护人员可以在运行过程中进行参数的修改,还可以读到各种统计数据,如起动的次数,运行的时间等,避免了生产中的停机,这对停机成本较高的生产具有十分重要的意义。
Win-SIMOCODE-DP/Smart是低价格的软件包,通过该软件可以通过RS232口对SIMOCODE-DP进行点对点的通讯。
Win-SIMOCODE-DP/Professional与Smart的界面格式与功能完全相同,不同是Professional除了可以通过RS232口通讯外还可以通过PROFIBUS-DP由工程师站对SIMOCODE-DP进行在线的参数设置、操作以及监测。除了正常的与PLC的数据传送循环之外,在线的操作功能还可以通过Class2的通讯处理器(如插在PC或编程设备中的CP5511)对SIMOCODE-DP的非循环参数(报警和统计数据)的读写进行控制。有了这种网络的在线方式,大大地方便了调试人员调试电机回路。
communication with the system network diginet s (iee802.3 Ethernet standard)
Interface.
Basic characteristics:
1ee802.3 Ethernet standard
o
Ei801f provides 10base2 thin cable communication interface
Ei802f provides 10BASE5 thick cable connection (through AUI interface)
Ei803f provides 10Base-T twisted pair communication interface
32-bit data bus, 100 mb/s
DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4%
Optional ram backup battery
Fieldbus interface replacement card fi830f/fi820f/fi810f
Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS,
Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still
It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other
Redundant basic unit pm802f) and can be plugged in and out and replaced online.
Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd
One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one city (subsystem) of industrial “system can
Connect 4960 fieldbus devices (10000 i/0).
Fi820f: two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association
Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation
Away. And the redundant operation is realized by two redundant field controllers.
Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station
The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured
-Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly.
S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus