GE DS200TCRAG1ACC
GE DS200TCRAG1ACC
GE DS200TCRAG1ACC
开关与保护设备
1 电动机保护断路器
2 接触器和接触器组合
3 中间继电器
4 过载继电器
5 软起动器
控制及信令装置
6 按钮和指示灯
7 信号灯柱和信号灯
8 行程开关
SIRIUS 继电器
9 时间继电器
10 监控继电器
11 接口继电器和变送器
可通讯控制与保护产品
12 执行器-传感器接口 AS-interface
13 ET200S 电机起动器
14 M200D 电机起动器
15 智能低压电机管理系统 SIMOCODE
安全继电器
16 SIRIUS 3TK28 安全继电器
17 SIRIUS 3RK3 安全继电器模块
connected at the same time (max. 12 MBD)
Simple project: only use the same tool CBF (control build f) software for configuration, debugging and diagnosis
mouth
Access to all information from the site, including equipment management information
Global database of Fieldbus equipment, control level and HMI (human-machine interface)
Module identification with production operating parameters
c
Complete self diagnosis
Compact and rugged design
Front panel wiring
DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient
o
Allowable operating ambient temperature 60 C, automatic temperature monitoring
o
EMC (electromagnetic compatibility) conforms to en50082 standard
mouth
Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd
Installation area: Class 1 div 2
The PS supports the following types of fieldbus standards:
Profibus DP,up to 12 MBd
Modbus RTU,1200 to 38. 4KBd
Industrial” CAN I/0 Bus
o
Open CAN -Bus,up to 1 MBd
o
Foundation Fieldbus H1
up to 31. 25KBd
Foundation Fieldbus H2 (fast Ethernet)
HART
The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS.
Industrial “field control explosion (AC800F) consists of the following components:
Basic unit pm802f
Power supply sa801f/sd802f
o
Ethernet network card ei801f/ei802f/ei803f
o
Fieldbus interface card fi810f/fi820f/fi830f
Various accessories
The main components of the field controller PS are described below.
Basic unit pm802f
The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the
The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed
The fieldbus interface card returns the corresponding fieldbus actuator.
Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS
Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a special
Redundant communication link (diginetr) to ensure information synchronization between master and slave PS. — However, the master PS fails, and the slave PS can quickly and undisturbed connect the replacement worker
Make. All inputs and outputs also support redundant operation.
The data communication between the field process controller PS. operating station 0s and the engineer station es is completed by the system network (diginets), which is inserted
The – Ethernet network card on the PS basic unit provides the interface between PS and diginets. ES. Hardware configuration and PS
The user program is downloaded to the PS CPU through diginets and the first network card. After the field bus interface card is newly installed or replaced, the required group
The status information will be automatically reloaded. The configuration results and real-time process data are stored in RAM, and ram is installed on the Ethernet network card or battery card
The backup battery can maintain the configuration content and data in case of power failure.
Basic unit pmbo2f characteristics:
mouth
Installation slots of 4 fieldbus interface cards
c
Installation slot of 2 Ethernet network cards
Support redundant operation of Fieldbus interface card
Support hot plug of Fieldbus interface card
Technical indicators of basic unit pib02f:
CPU :Intel 80960HT25/75
32-bit RISC superscalar processor with operation speed of 150 MIPS
4 MB FLASH-EPROM
EEPROM,serial, 16 Kbit
o
Ram 8 MB (with error check and correction function, abb patent)
16 K internal cache (CPU cache RAM)
Ram backup battery (matchdog, optional redundancy)
Equipment internal temperature monitoring
Watchdog
I/0 sweeping cycle: configurable.
Time required to process 1000 IL (instructions):
< 1.0 ms (processing binary and 16 bit arithmetic instructions)
<2ms (processing fixed-point arithmetic instructions)
< 1.5ms (processing 32-bit floating-point arithmetic instructions)
Bthernet network card ei801f/ei802f/ei803f
The industrial Ethernet network card provides